home *** CD-ROM | disk | FTP | other *** search
/ MacWorld 1998 March / Macworld (1998-03) (Disk 1).dmg / Updaters / OMNIS 7 3.6.3 PPC / README.TXT < prev   
Text File  |  1997-12-23  |  17KB  |  263 lines

  1. OMNIS 7 V3.6.3 Patch
  2.  
  3. README.TXT
  4.  
  5. December 23, 1997
  6.  
  7. IMPORTANT NOTES:
  8. This patch fixes specific problems that were reported against all platform versions of OMNIS 7 V3.6, the 3.6.1 Patch for the Macintosh and Power Macintosh platforms, and the 3.6.2 Patch for all platforms. The files contained in this patch can only be used to replace certain V3.6.x files, is available only to licensees of OMNIS 7 V3.6 and therefore licensed under the same terms and conditions set forth in the OMNIS 7 V3.6 product packaging. 
  9.  
  10. Web Enabler and Web RAD:
  11. 1. Installing this patch on top of a Web Enabled version of OMNIS 7 V3.6 replaces the TCPSock external in your External/Omnis Extensions folder only; it does not replace copies of the file elsewhere on your system. Previous Windows 95 and Windows NT versions of Web Enabler or Web RAD may include a file called either TCPSock32.dll or TCPSoc32.dll. The file is called TCPSock32.dll in this patch regardless of the name of the previous version. 
  12.  
  13. 2. Installing this patch on top of a Web Enabled version of OMNIS 7 V3.6 for Windows 95 and Windows NT replaces the FTPCLN32.DLL external in your External folder only; it does not replace copies of the file elsewhere on your system. This new extension fixes a problem with the 'FTPList()' command discovered in the Windows 95 and Windows NT versions reported by one customer. (See ST/EC/223FC below.)
  14.  
  15.  
  16. CONTENTS
  17. ----------------
  18.  
  19. 1. Installation Instructions
  20.  
  21. 2. Faults Fixed
  22.     2.1 Faults Fixed in 7.3.6.3
  23.     2.2 Faults Fixed in 7.3.6.2
  24.     2.3 Faults Fixed in 7.3.6.1
  25.  
  26. 3. Notes and Cautions
  27.  
  28.  
  29. 1. Installation Instructions
  30. --------------------------------
  31.  
  32. To install the 3.6.3 Patch:
  33. 1. Open the appropriate folder for the platform on which you wish to install.
  34. 2. Select either the development or runtime folder as appropriate.
  35. 3. Launch the Setup/Install utility located in this folder.
  36. 4. Follow the instructions in the installer. This will include entering your OMNIS 7 serialization details. 
  37.  
  38. You are now ready to use the OMNIS 7 V3.6.3 Patch.
  39.  
  40. Installation Notes: 
  41.  
  42. 1. The Uninstall option for the Windows OS versions removes only the files supplied in this patch, not the whole of OMNIS 7. 
  43.  
  44. 2. The 3.6.3 Patch installs a new Serial.exe for all platforms that provides the added convenience of reserialising the OMNIS executable after installation. If you have a text file containing: 
  45.  
  46.     drive/path/name
  47.     User Name
  48.     Company Name
  49.     Serial Number
  50.  
  51. and drag this file onto Serial.exe, it will reserialise the executable for you. For example: 
  52.  
  53.     c:/programs/omnis/omnis7.exe
  54.     George Bailey
  55.     Bailey Thrift & Loan
  56.     CMDSI 123456 54321
  57.  
  58.  
  59. 2. Faults Fixed
  60. ------------------
  61.  
  62. This section describes the fixes for both the 7.3.6.3 Patch, the 7.3.6.2 Patch, and the 7.3.6.1 Patch. The Fixes and Notes contain a reference number such as "OC/RU/412FC" which identifies the problem in the OMNIS Software faults database. Some faults may have a different prefix, such as "ST" for OMNIS Studio faults; but these apply equally to OMNIS 7, when noted, and have been fixed in this release.
  63.  
  64. 2.1 Faults Fixed in the OMNIS 7.3.6.3 Patch
  65. -------------------------------------------------
  66.  
  67. OC/AH/101FC    Platform(s): All
  68. All calculated fields specified in an Ad hoc report are now used to sort the report.
  69.  
  70. OC/AH/102FC    Platform(s): All
  71. Ad hoc reports that join two or more tables now execute correctly in design mode. 
  72.  
  73. OC/ET/077    Platform(s): All
  74. A fix in 7.3.6.2 for external areas has been reversed. Hence the xfcsetup message sets up the field name and reference correctly as in 7.3.6.1 and earlier versions. 
  75.  
  76. OC/PC/207FC    Platform(s): Windows 95 and Windows NT
  77. The bottom margin of a report is no longer affected when using the 'Begin print job' and 'End print job' commands when printing multiple reports in a batch.  
  78.  
  79. OC/PF/078FC    Platform(s): Mac OS 
  80. The speed of redrawing fields on windows containing 200 or more objects has been improved. 
  81.  
  82. OC/WO/682    Platform(s): All
  83. Horizontal scroll bars in entry fields inside table objects now function correctly.
  84.  
  85. ST/EC/223FC    Platform(s): Windows 95 and Windows NT
  86. The FTPList() command no longer results in errors when running in conjunction with an Windows NT 4.0 FTP Server in which OMNIS and the OMNIS application were invoked multiple times over short time intervals, such as a few clock ticks to several seconds.
  87.  
  88.  
  89. 2.2 Faults Fixed in the OMNIS 7.3.6.2 Patch
  90. ------------------------------------------------------
  91.  
  92. This section contains a cumulative list of faults fixed since the release of both OMNIS 7 V3.6 for all platforms and the 3.6.1 Patch for the Macintosh and Power Macintosh platforms.  
  93.  
  94. PR/@O/040FC    Platform(s): All 
  95. The Oracle DAM now handles select tables returned using Oracle stored procedures. Although Oracle can return select tables with multiple columns through stored procedures, it does not allow multi-column arrays to be bound to multi-column tables. Oracle limits binding to tables to one column only. Therefore, to return a select table through a stored procedure each column of the select table must be passed back as a separate parameter to the procedure. To bind a column of a list to a stored procedure you must use the following syntax: :list_name[(num_rows)].col_name where num_rows is the maximum number of rows in the list to bind. If the procedure returns more rows than there are allocated an error will result. If you don't specify the number of rows, a default value is used. 
  96.  
  97. OC/@O/072    Platform(s): All 
  98. Adding the size of buffer after an updateable bind variable in PL/SQL block no longer requires a trailing space or new line character for it to work. Updateable bind variables can now be followed directly by commas and parentheses, hence Begin GetName(1, :mybindvar:1024); End; and Begin GetName(:mybindvar:1024, 1); End; both now work. 
  99.  
  100. OC/@O/076    Platform(s): All 
  101. Bind variables of insufficient length passed as OUT parameters in PL/SQL no longer cause a crash. The Server specific keyword <TRAILINGSPACES> ON/OFF has been added that lets you switch trailing spaces on or off in Oracle; it is OFF by default. 
  102.  
  103. OC/@O/078FC & PR/@O/036    Platform(s): All 
  104. The server specific keyword NULLASEMPTY now returns all null values as empty. 
  105.  
  106. OC/@O/079    Platform(s): All 
  107. You can now see table columns when creating an Oracle SQL Ad hoc report (when $sqladhocalltables is set to kTrue). 
  108.  
  109. OC/@O/084    Platform(s): All 
  110. You can now insert and retrieve NULLS from LONG RAW columns in an Oracle database. 
  111.  
  112. OC/@O/094FC    Platform(s): All 
  113. Including parentheses in a Select statement, such as (SELECT * FROM TABLE), no longer causes problems when using the Oracle DAM. 
  114.  
  115. OC/@O/104    Platform(s): All 
  116. The 'Describe table' command now returns LONG as Character data with length 10,000,000. In addition, the 'Make file format from table' command creates a Character column with length 10,000,000. 
  117.  
  118. OC/@O/105FC    Platform(s): Power Mac 
  119. The Power Mac Oracle DAM now works with the most recent version of SQL*Net 2.3.x and no longer depends on the additional SQL*Net 7.1.4.1.x Required Support Files. 
  120. CAUTION: please note that in order to make a connection to Oracle from the Power Mac version of OMNIS 7 V3.6.2, you must use SQL*Net V2.3.2.0.0 with Required Support Files V7.3.2.1.1 or later, which fixes Oracle Bug 505203 "Oracle customer can only connect using SQL*Plus," and is available only from Oracle Technical Support (or by way of purchasing the latest version of Developer 2000 from Oracle Corporation). Ensure that you refer to Oracle Bug 505203 when contacting Oracle Technical Support or Oracle Sales and that you receive file "OracleOci73Lib V3.5.2.0.1" or higher in response. (Also see OC/@O/101FC in the Notes and Cautions section below.)
  121.  
  122. OC/@O/106    Platform(s): All 
  123. Oracle LONG and LONG RAW data types can now be fetched correctly when re-executing the fetch. 
  124.  
  125. OC/@O/110 & ST/@O/099    Platform(s): All 
  126. The Oracle DAM now reads Booleans as numeric values, hence foreign language versions of OMNIS 7 V3.6.2 will now send proper Boolean values to Oracle. 
  127.  
  128. OC/@O/111    Platform(s): All
  129. You can now use correlation names :old and :new in a create trigger statement. 
  130.  
  131. OC/AE/007FC    Platform(s): Mac OS 
  132. The Word Services Apple events in OMNIS 7 V3.6.2 that enable editing tools such as SpellsWell(tm) now work correctly. 
  133.  
  134. OC/AH/095    Platform(s): Mac OS
  135. Creating an Ad hoc report using an OMNIS 7 data file no longer causes a Type 11 error. 
  136.  
  137. OC/CO/211    Platform(s): Mac OS 
  138. Converting OMNIS 7 V1 applications using V3.6.2 now work correctly. 
  139.  
  140. OC/DF/020 & ST/DF/021    Platform(s): All 
  141. Inserting data into a data file with a locked record no longer corrupts indexes. 
  142.  
  143. OC/DF/022    Platform(s): Windows OS 
  144. OMNIS 7 V3.6.2 applications that run on a server now locate multi-segment data files successfully. 
  145.  
  146. OC/EC/133FC    Platform(s): Mac OS 
  147. Clicking the mouse in an external area no longer causes a memory leak. 
  148.  
  149. OC/ET/051FC    Platform(s): Windows 95 and Windows NT 
  150. Long file names for ALL external DLLs is now supported. 
  151.  
  152. OC/ET/057    Platform(s): All 
  153. The syntax for the DIROPS commands has reverted back to its V3.5 usage; that is, the listname, columnname, and path parameters can, as before, be enclosed in quotes. 
  154.  
  155. OC/ET/065FC    Platform(s): Power Mac 
  156. Path strings longer than 127 characters and up to 255 characters returned using the 'Get Files' command no longer cause a system hang. 
  157.  
  158. OC/ET/067FC    Platform(s): Power Mac 
  159. On page 6-45 and 6-93 of the Extending OMNIS manual the description of the fmt_hpict format is misleading. When used with the GetFldVal and SetNamedVal functions you don't need to create the handle yourself, but you should still dispose of the handle. You should pass in a NULL handle, and the handle is created by the function. 
  160.  
  161. OC/FU/104FC    Platform(s): All 
  162. The 'Get file read-only attribute' and 'Set file read-only attribute' commands have been added to the FileOps external command package. 'Get file read-only attribute (path, read-flag)' returns the current read-only attribute of the file specified in path. If the read-flag parameter returns kTrue the file is read-only; otherwise if kFalse, the file is read/write. 'Set file read-only attribute (path, read-flag)' lets you set the read-only attribute of the file specified in the path. If you set the read-flag parameter to kTrue the file is set to read-only; or if kFalse, the file is set to read/write. Note that read-only status is the same as locked under Mac OS. Both commands return any error code (documented in the Reference manual), or zero if none. 
  163.  
  164. OC/FU/113FC    Platform(s): Mac OS 
  165. The 'Open client import file' command now opens and appends data to an existing import file correctly. 
  166.  
  167. OC/FU/114FC    Platform(s): Windows OS 
  168. The 'Retrieve rows to file' command now appends data to the current import file correctly. 
  169.  
  170. OC/FU/126    Platform(s): All 
  171. The dname() function now returns the correct value if the day of the week is a Saturday. 
  172.  
  173. OC/HI/804FC    Platform(s): Windows 95
  174. You can now move and resize windows when the primary mouse button is set to left-handed usage in the Windows 95 Control Panel. 
  175.  
  176. OC/HI/841    Platform(s): Mac OS 
  177. Using the CTRL key and certain letter keys in OMNIS 7 for Mac OS no longer cause unexpected results. 
  178.  
  179. OC/NT/169FC    Platform(s): All 
  180. You can now write the 'Build list from select table' command into procedure text using the notation. In addition the command is not changed at all when you switch to free-type mode in the procedure editor. 
  181.  
  182. GR/OL/072    Platform(s): Windows OS
  183. Reports containing OLE picture fields now print correctly. In addition OLE picture fields in reports, with the Do not scale option unchecked, are now scaled correctly (Although, please see fault OC/OL/030FC in the Notes and Cautions section below). 
  184.  
  185. OC/OL/026 & PR/OL/022FC    Platform(s): Windows OS 
  186. OLE1 objects inserted into an OMNIS 7 data file under Windows 3.1 are now supported in OLE2 under Windows 95. 
  187.  
  188. OC/OL/029FC    Platform(s): Windows OS 
  189. Windows are now being redrawn properly when returning to OMNIS 7 from palette applications that use 256 colors. 
  190.  
  191. ST/OL/035 & ST/OL/036    Platform(s): Windows 95 
  192. Microsoft clip art and Word art 2.0 pictures now display correctly in OMNIS 7. 
  193.  
  194. OC/PF/057FC    Platform(s): Windows 95 and Windows NT 
  195. The "OmnisPic.DF1 data file missing" error message no longer appears when you drag-and-drop a library file onto the OMNIS 7 executable in the Windows 95 and Windows NT versions. However, if you drag-and-drop a library file onto the OMNIS 7 executable of a developer instance of OMNIS 7 that is set to load the Developer Shell, please see fault OC/HI/888FC in the Notes and Cautions section below. 
  196.  
  197. OC/PF/059    Platform(s): Windows 95 
  198. Speed performance has been improved for serial port communications in the Windows 95 version. 
  199.  
  200. OC/PF/064    Platform(s): Windows NT only 
  201. DDE operations no longer cause crashes when using the Windows NT version. 
  202.  
  203. OC/PF/066    Platform(s): Mac OS 
  204. Clicking in the Finder while executing 'Prompt for...' commands no longer causes OMNIS 7 to hang. 
  205.  
  206. OC/PF/072    Platform(s): Windows NT v3.51 only 
  207. Under Windows NT 3.51 only, OMNIS 7 no longer quits when you close the Attributes window for a window object. 
  208.  
  209. OC/PF/073    Platform(s): Mac OS 
  210. Memory and performance problems reported against the OMNIS 3.6.1 Patch for Mac OS no longer occur. 
  211.  
  212. OC/RC/255FC    Platform(s): Mac OS 
  213. Screen reports and reports to the printer and are no longer corrupted when you click on the Mac OS menu bar while the report is in progress. 
  214.  
  215. OC/RC/271    Platform(s): Windows OS 
  216. A 'Discard previous settings' check box option has been added to the 'Select printer' command. When checked the page setup for the newly selected printer is always used, otherwise if the option is unchecked the page setup from the previous printer is used (initially this is the default printer). 
  217.  
  218. OC/VR/104    Platform(s): All 
  219. Initial value calculations for local variables are now re-tokenized correctly when formats containing the variables are copied between libraries. 
  220.  
  221. OC/VR/109    Platform(s): Windows 3.1 
  222. Exponential numbers are now recognized in the Windows 3.1 version. 
  223.  
  224. WD/TS/031FC    Platform(s): All 
  225. The TCPReceive command now handles binary data sent to OMNIS 7 via TCP/IP. 
  226.  
  227. WD/TS/032FC    Platform(s): All 
  228. The parameter description for the TCPSend command is now (socket, character|binary). 
  229.  
  230.  
  231. 2.3 Faults Fixed in the OMNIS 7.3.6.1 Patch
  232. ------------------------------------------------------
  233.  
  234. This section contains faults fixed in the Macintosh and Power Macintosh versions of OMNIS 7 V3.6. 
  235.  
  236. OC/@O/089FC    Platform(s): Power Mac 
  237. The Oracle DAM now closes successfully after using the 'Logoff from host' and 'Quit cursor(s)' commands. 
  238.  
  239. OC/PF/055    Platform(s): Mac OS 
  240. OMNIS 7 v3.6.1 and higher for Mac OS supports Apple's Mac OS 8 operating system. If you are using the DAMs under Mac OS 8 you should contact your clientware vendor(s) to ensure Mac OS 8 compatibility for the respective clientware. 
  241.  
  242. OC/PF/061    Platform(s): Mac OS 
  243. Adding items to the CRB no longer causes a memory leak. 
  244.  
  245. OC/PF/068FC    Platform(s): Mac OS 
  246. Memory and performance problems reported against OMNIS 7 V3.6 for Mac OS no longer occur. 
  247.  
  248.  
  249. 3. Notes and Cautions
  250. ---------------------------
  251.  
  252. OC/@O/101FC    Platform(s): Power Mac 
  253. There is a memory leak of approximately 64k every time you log on and log off from an Oracle server using the Oracle DAM. This problem is caused by Oracle Bug 569353 contained in the Mac version of SQL*Net 2.3.2.0.0 when connecting using OCI. The fix for this bug is contained in "OracleNetTNSLib V2.3.2.0.2" and is available only from Oracle Technical Support (or by way of purchasing the latest version of Developer 2000 from Oracle Corporation). Ensure that you refer to Oracle Bug 569353 when contacting Oracle Technical Support or Oracle Sales and that you receive file "OracleNetTNSLib V2.3.2.0.2" or higher in response.
  254.  
  255. OC/HI/888FC    Platform(s): Windows OS 
  256. Error messages from the O7DShell.lbr still occur when you drag-and-drop a library file onto the OMNIS 7 executable. Although the fix to OC/PF/057FC eliminates the executable error message "OmnisPic.DF1 data file missing," for all runtime and developer instances of OMNIS 7, the O7DShell.lbr still displays the OMNISPIC.DF1 data file prompt dialog, and if canceled, the error messages: "Because the icons file was not found and opened, certain parts of the Omnis Shell may appear incorrect" and "The icons file could not be opened. This will affect the presentation of the Environment."
  257.  
  258. OC/OL/030FC    Platform(s): Windows OS 
  259. Pictures inserted from PowerPoint are shown a quarter of their correct size, that is, the height and width are each half the correct amount. Other programs, such as Word have the same problem. It appears that PowerPoint is supplying the wrong information, not just to the OMNI2OLE.DLL, but to any program. 
  260.  
  261. [END OF FILE]
  262.  